Hana Abernath: Heart failure

ENC-00062 · 53M · Hospital Medicine · admitted Fri Oct 30, 2026 11:17 AM · discharged Tue Nov 03, 2026 01:25 PM · attending Dr. Isaac Abernath · resident Dr. Keira Upfield

Specificity gap Criteria met Open

Documented “congestive heart failure” (I50.9); criteria support the more specific Acute on chronic systolic (HFrEF) heart failure (I50.23).

Documented vs supported

Documented
“congestive heart failure” · I50.9 Heart failure, unspecified
Criteria support
Acute on chronic systolic (HFrEF) heart failure · I50.23 Acute on chronic systolic (congestive) heart failure
Outcome
LVEF 34% with 3 acute indicators and prior heart failure
Rule
Heart failure type (LVEF) and acuity v2026.11-1
Published source
Universal Definition and Classification of Heart Failure (HFSA/HFA/JHFS, 2021), as restated in Chandramouli et al., Clin Cardiol 2022 (2021), LVEF classification: HFrEF <=40%, HFmrEF 41-49%, HFpEF >=50%; HFimpEF = baseline <=40%, rise >=10 points, second LVEF >40% · source (checked 2026-11-14)
Contested
No guideline gives a numeric definition of "acute" versus "chronic" heart failure. This rule uses a LOCAL CONVENTION: at least two acute indicators (IV loop diuretic, elevated natriuretic peptide, new oxygen requirement) = acute; with a prior history of heart failure = acute on chronic; none with history = chronic; exactly one = clinical judgement.

Effect if the clinician agrees (illustrative)

Change
I50.9 -> I50.23
Secondary-diagnosis level
non-CC → MCC
MS-DRG (illustrative)
872 Septicemia or severe sepsis without MV >96 hours without MCC → 871 Septicemia or severe sepsis without MV >96 hours with MCC
Relative weight
1.0233 → 1.9425 (+0.9192)
Codes before
A41.9, N39.0, E46, N18.9, N17.9, I50.9, R09.02, I10, E78.5, E11.9
Codes after
A41.9, N39.0, E46, N18.9, N17.9, R09.02, I10, E78.5, E11.9, I50.23

All open gaps on this encounter together: MS-DRG 872 → 871 (RW +0.9192).

CC/MCC status, CC exclusions (subset) and relative weights from the public CMS FY2026 IPPS final rule tables (5, 6I, 6J, 6K). This is not a grouper and not a payment estimate. Queries never mention any of this.

Severity documentation index change SIMULATED

1.0 points

SIMULATED: Illustrative severity weights (MCC = 1.0, CC = 0.5, non-CC = 0) summed over secondary diagnoses; not a validated risk-adjustment model and not a measured effect.

Evidence

Structured values are read by code from the cited rows. Note facts are shown only when the model's quote was found verbatim in the note.

Evidence (each item cited to a source row or a quoted span)
InputValueSource
Latest LVEF within 12 months (%) 34.0
echo LVEF 34% · echo ECH-000029 · 2026-10-31 02:17
IV loop diuretic given this stay True
furosemide 40 mg IV · med MED-000234 · 2026-10-30 20:00
furosemide 40 mg IV · med MED-000235 · 2026-10-31 08:00
furosemide 40 mg IV · med MED-000236 · 2026-10-31 20:00
furosemide 40 mg IV · med MED-000237 · 2026-11-01 08:00
Highest BNP this stay (pg/mL) 1775.0
BNP 1775 pg/mL · lab LAB-002101 · 2026-10-30 12:17
Supplemental oxygen started this stay without home oxygen
supplemental oxygen started this stay without home oxygen on file
True
O2 6 L/min (nasal cannula) · vital VIT-006027 · 2026-10-30 11:47
Prior heart failure on the problem list / history True
history: heart failure with reduced ejection fraction · history HX-000022
Rule trace (inputs, thresholds, outcome)
Rule trace (rule heart_failure v2026.11-1; evaluated in order, first true outcome wins; "unknown" = missing input)
StepExpressionInputs and thresholds readResult
derived: np_elevated coalesce(bnp_max >= t.bnp, false) or coalesce(ntprobnp_max >= t.ntprobnp, false) bnp_max=1775.0, ntprobnp_max=unknown, t.bnp=100, t.ntprobnp=300 true
derived: acute_count count(iv_loop_diuretic, np_elevated, new_o2) iv_loop_diuretic=True, new_o2=True, np_elevated=True 3
derived: hf_type case(lvef <= t.ref, 'systolic', lvef >= t.pres, 'diastolic', 'midrange') lvef=34.0, t.pres=50, t.ref=40 systolic
derived: improved coalesce(lvef_prior_min <= t.ref and lvef > t.ref and lvef - lvef_prior_min >= t.improved_rise, false) lvef=34.0, lvef_prior_min=unknown, t.improved_rise=10, t.ref=40 false
derived: acuity case(acute_count >= 2 and hf_history, 'acute on chronic', acute_count >= 2, 'acute', acute_count == 0 and hf_history, 'chronic', null) acute_count=3, hf_history=True acute on chronic
outcome: improved_ef improved improved=False false
outcome: midrange hf_type == 'midrange' hf_type=systolic false
outcome: sys_aoc hf_type == 'systolic' and acuity == 'acute on chronic' acuity=acute on chronic, hf_type=systolic true

Documentation query

Title and question drafted by model clockworks-mock (audit entry #2086); clinical indicators and answer options assembled by code from the rule and the record.

Sign in to act. Sign in as a demo user (a CDI specialist sends queries).

DOCUMENTATION QUERY (draft)
Title: Clarification request: cardiac documentation
Encounter: ENC-00062   Patient: Hana Abernath   To: Dr. Isaac Abernath

Clinical indicators from the health record:
- Documented in the record: "congestive heart failure" [Progress note DOC-000215]
- echo LVEF 34% (2026-10-31 02:17) [echo ECH-000029]
- furosemide 40 mg IV (2026-10-30 20:00) [med MED-000234]
- furosemide 40 mg IV (2026-10-31 08:00) [med MED-000235]
- furosemide 40 mg IV (2026-10-31 20:00) [med MED-000236]
- furosemide 40 mg IV (2026-11-01 08:00) [med MED-000237]
- BNP 1775 pg/mL (2026-10-30 12:17) [lab LAB-002101]
- O2 6 L/min (nasal cannula) (2026-10-30 11:47) [vital VIT-006027]
- history: heart failure with reduced ejection fraction [history HX-000022]

Question:
Based on your clinical judgement and the indicators above, can the type and acuity of the heart failure being treated be further specified?

Response options (select one or write your own):
( ) Acute on chronic systolic heart failure (HFrEF)
( ) Chronic systolic heart failure (HFrEF)
( ) Other (please specify): ____________
( ) Unable to determine

Please respond based on your independent clinical judgement. Any response, including "unable to determine", is acceptable. This query and your response are kept as part of the health record.

Other findings on this encounter

History

Audit entries for this finding (newest first)
SeqWhen (UTC)ActorAction EntitiesDecision / reasonModel / hashes
2086 2026-11-14T20:57:24 system:llm
system
llm.call ENC-00062, ENC-00062.heart_failure — clockworks-mock mock-1/exactdx.draft_query@1
prompt 97eeabcf72dd
output 752ce96b1cd3
entry a6db28fb5cd3
1260 2026-11-14T19:24:29 system:llm
system
llm.call ENC-00062, ENC-00062.heart_failure — clockworks-mock mock-1/exactdx.draft_query@1
prompt 97eeabcf72dd
output 752ce96b1cd3
entry 0ecd7c8115ae
518 2026-11-14T18:29:04 system:llm
system
llm.call ENC-00062, ENC-00062.heart_failure — clockworks-mock mock-1/exactdx.draft_query@1
prompt 97eeabcf72dd
output 752ce96b1cd3
entry fcd4a739b57a