Skip to main content
Exact Dx synthetic data · demonstration
Extended criteria (experimental). This is the broader ten-condition engine, kept as a secondary area. It shows ICD-10-CM codes and illustrative grouping effects for CDI staff. The primary surface is Before you sign (kidney, measurement only). All extended pages.

← Back to the worklist · Whole encounter ENC-00074

Ximena Bellweather: Acute respiratory failure

ENC-00074 · 87M · Hospital Medicine · admitted Tue Nov 10, 2026 02:08 PM · in hospital · attending Dr. Rosalind Quillan · resident Dr. Priya Thorne

Specificity gap Criteria met Open In hospital: concurrent review Resident note awaiting attending cosign

Criteria support Acute respiratory failure with hypoxia (J96.01); no corresponding diagnosis is documented.

Documented vs supported

Documented
not documented
Criteria support
Acute respiratory failure with hypoxia · J96.01 Acute respiratory failure with hypoxia
Outcome
Hypoxaemia criterion met with a sign of respiratory distress
Rule
Acute hypoxic respiratory failure v2026.11-1
Published source
Merck Manual Professional Version: Acute Hypoxemic Respiratory Failure (AHRF), including ARDS (2026), Definition/evaluation: PaO2 <60 mmHg, PaO2/FiO2 <300, or SpO2 <88%, with dyspnea and tachypnea · source (checked 2026-11-14)
Contested
Organizations use different oxygen-saturation cut-offs (SpO2 <88%, <=90% or <91% on room air). This rule uses <88% (the source above) and a LOCAL respiratory-rate cut-off of 28/min as one sign of respiratory distress.

Effect if the clinician agrees (illustrative)

Change
add J96.01
Secondary-diagnosis level
— → MCC
MS-DRG (illustrative)
871 Septicemia or severe sepsis without MV >96 hours with MCC → 871 Septicemia or severe sepsis without MV >96 hours with MCC
Relative weight
1.9425 → 1.9425 (+0.0000)
Codes before
A41.9, J18.9, E66.9, I10, E11.9
Codes after
A41.9, J18.9, E66.9, I10, E11.9, J96.01

All open gaps on this encounter together: MS-DRG 871 → 871 (RW +0.0000). The grouping does not change; the record becomes accurate.

CC/MCC status, CC exclusions (subset) and relative weights from the public CMS FY2026 IPPS final rule tables (5, 6I, 6J, 6K). This is not a grouper and not a payment estimate. Queries never mention any of this.

Severity documentation index change SIMULATED

1.0 points

SIMULATED: Illustrative severity weights (MCC = 1.0, CC = 0.5, non-CC = 0) summed over secondary diagnoses; not a validated risk-adjustment model and not a measured effect.

Evidence

Structured values are read by code from the cited rows. Note facts are shown only when the model's quote was found verbatim in the note.

Evidence (each item cited to a source row or a quoted span)
InputValueSource
Lowest SpO2 on room air (%) 84.0
SpO2 84% on room air · vital VIT-007258 · 2026-11-10 14:28
Highest respiratory rate (/min) 32.0
respiratory rate 32/min · vital VIT-007259 · 2026-11-10 14:28
Highest supplemental oxygen flow (L/min) 5.0
O2 5 L/min (nasal cannula) · vital VIT-007260 · 2026-11-10 14:38
Increased work of breathing quoted from a note True
“increased work of breathing” · History and physical DOC-000256, p. 1, line 8 · quoted span verified
Show the quote in the note
… neumonia; blood cultures drawn and ceftriaxone started. Past medical history: hypertension, type 2 diabetes. Review of systems otherwise negative. Exam: Lungs: increased work of breathing with accessory muscle use. Assessment and plan: 1. Sepsis: antibiotics, fluids. 2. Community-acquired pneumonia: antibiotics.
Rule trace (inputs, thresholds, outcome)
Rule trace (rule respiratory_failure v2026.11-1; evaluated in order, first true outcome wins; "unknown" = missing input)
StepExpressionInputs and thresholds readResult
derived: measured present(spo2_min_ra) or present(pao2_min_ra) or present(pf_min) pao2_min_ra=unknown, pf_min=unknown, spo2_min_ra=84.0 true
derived: hypoxemia coalesce(spo2_min_ra < t.spo2_ra, false) or coalesce(pao2_min_ra < t.pao2, false) or coalesce(pf_min < t.pf, false) pao2_min_ra=unknown, pf_min=unknown, spo2_min_ra=84.0, t.pao2=60, t.pf=300, t.spo2_ra=88 true
derived: distress coalesce(rr_max >= t.rr_distress, false) or coalesce(wob_increased, false) or adv_resp_support adv_resp_support=False, rr_max=32.0, t.rr_distress=28, wob_increased=True true
outcome: chronic_baseline home_o2 and hypoxemia home_o2=False, hypoxemia=True false
outcome: met hypoxemia and distress distress=True, hypoxemia=True true

Documentation query

Title and question drafted by model clockworks-mock (audit entry #2117); clinical indicators and answer options assembled by code from the rule and the record.

Sign in to act. Sign in as a demo user (a CDI specialist sends queries).

DOCUMENTATION QUERY (draft)
Title: Clarification request: respiratory documentation
Encounter: ENC-00074   Patient: Ximena Bellweather   To: Dr. Rosalind Quillan

Clinical indicators from the health record:
- SpO2 84% on room air (2026-11-10 14:28) [vital VIT-007258]
- respiratory rate 32/min (2026-11-10 14:28) [vital VIT-007259]
- O2 5 L/min (nasal cannula) (2026-11-10 14:38) [vital VIT-007260]
- "increased work of breathing" (2026-11-10 17:08) [History and physical DOC-000256, p. 1, line 8]

Question:
Based on your clinical judgement and the indicators above, can the respiratory diagnosis being evaluated and treated be further specified?

Response options (select one or write your own):
( ) Acute respiratory failure with hypoxia
( ) Hypoxemia without respiratory failure
( ) Other (please specify): ____________
( ) Unable to determine

Please respond based on your independent clinical judgement. Any response, including "unable to determine", is acceptable. This query and your response are kept as part of the health record.

Other findings on this encounter

History

Audit entries for this finding (newest first)
SeqWhen (UTC)ActorAction EntitiesDecision / reasonModel / hashes
2117 2026-11-14T20:57:24 system:llm
system
llm.call ENC-00074, ENC-00074.respiratory_failure — clockworks-mock mock-1/exactdx.draft_query@1
prompt f94cfa3b4fef
output 5de8fced5850
entry e9a4c5d0430f
1291 2026-11-14T19:24:29 system:llm
system
llm.call ENC-00074, ENC-00074.respiratory_failure — clockworks-mock mock-1/exactdx.draft_query@1
prompt f94cfa3b4fef
output 5de8fced5850
entry bad4eb099c20
549 2026-11-14T18:29:04 system:llm
system
llm.call ENC-00074, ENC-00074.respiratory_failure — clockworks-mock mock-1/exactdx.draft_query@1
prompt f94cfa3b4fef
output 5de8fced5850
entry 31574baa67bd