Skip to main content
Exact Dx synthetic data · demonstration

Coder worklist · Clinician screen · Chart

Staff surface Coder view

P16 KE-P16 · inpatient visit

One row per condition family: what the record supports under the published definition, what the note states, the visit's diagnosis entries, and an assessment. Codes are coded from the signed documentation; the software never assigns one.

Library check LRUN-00016 · library_default_set@1.0 · library-engine 1.0 · replay df3873637fe81bb6… · Data (JSON)

Condition families for this encounter (4)
Condition familyWhat the record supportsWhat the note states Visit diagnosis entriesAssessment
Hypoglycaemia (in people with diabetes)
measured

ada2026_hypoglycaemia@1.0 Draft · pending review

Level 1: glucose <70 mg/dL (<3.9 mmol/L) and ≥54 mg/dL (≥3.0 mmol/L)

  • glucose plasma 62 mg/dL 2026-11-12 06:00 · LM-P16-04

Window: 14 days before the check.

Citation

Hypoglycaemia level (ADA Standards of Care 2026)

ada2026_hypoglycaemia@1.0
Level 1: Glucose <70 mg/dL (<3.9 mmol/L) and ≥54 mg/dL (≥3.0 mmol/L). Level 2: Glucose <54 mg/dL (<3.0 mmol/L). Level 3: A severe event characterized by altered mental and/or physical status requiring assistance for treatment of hypoglycemia

American Diabetes Association Professional Practice Committee, 6. Glycemic Goals, Hypoglycemia, and Hyperglycemic Crises: Standards of Care in Diabetes—2026 (2026) · Table 6.4 Classification of hypoglycemia · source

Contested: The International Hypoglycaemia Study Group (2017) sets level 1 at 'a glucose alert value of 3.9 mmol/l (70 mg/dl) or less', i.e. it includes exactly 70 mg/dL; ADA 2026 uses '<70'. CTCAE uses other cut-offs.

Not encoded: Level 3 is clinical: it is reported only when the caller supplies severe_event_requiring_assistance = true; otherwise it is skipped with a note. Whether the glucose came from a meter, CGM or laboratory is not distinguished; CGM duration criteria (for example 15 minutes) are not stated in the opened table and are not encoded.

Not stated

E16.2 Hypoglycemia, unspecified (visit diagnosis list (synthetic))

Supported, but entered or stated less specifically than the record supports

entered E16.2 (Hypoglycemia, unspecified)

The code family distinguishes: hypoglycaemia level 1, level 2, level 3 (E16.A1-E16.A3, new; not yet in the 2027 initial HCC file), drug-induced without coma, other, unspecified; in diabetes the combination codes E08-E13 with .64- are used.

Draft a query

Code-family reference: Hypoglycaemia (in people with diabetes) Coders only

reference for coders — the clinician's documented statement governs; the software does not assign codes

E16 Other disorders of pancreatic internal secretion: distinguishes hypoglycaemia level 1, level 2, level 3 (E16.A1-E16.A3, new; not yet in the 2027 initial HCC file), drug-induced without coma, other, unspecified; in diabetes the combination codes E08-E13 with .64- are used (10 codes in the category).

  • E16.0 Drug-induced hypoglycemia without coma
  • E16.1 Other hypoglycemia
  • E16.2 Hypoglycemia, unspecified
  • E16.3 Increased secretion of glucagon
  • E16.4 Increased secretion of gastrin
  • E16.8 Other specified disorders of pancreatic internal secretion
  • E16.9 Disorder of pancreatic internal secretion, unspecified
  • E16.A1 Hypoglycemia level 1
  • E16.A2 Hypoglycemia level 2
  • E16.A3 Hypoglycemia level 3

E11 Type 2 diabetes mellitus: distinguishes type 2 diabetes with hypoglycaemia with or without coma (E11.64-) (87 codes in the category).

87 codes; see the official files

Codes in this family for the category the record supports: E16.A1 Hypoglycemia level 1.

Source: official ICD-10-CM FY2027 code descriptions (extract in library/data/code_reference_fy2027.json).

Diabetes mellitus
measured

ada2026_diabetes@1.0 Draft · pending review

Diabetes criteria met: two abnormal results (different tests, or the same test at two times)

  • hba1c 8.2 % 2026-09-12 09:00 · LM-P16-02

Window: 730 days before the check.

Citation

Diabetes diagnostic thresholds and the confirmation rule (ADA Standards of Care 2026)

ada2026_diabetes@1.0
Table 2.1: A1C ≥6.5% (≥48 mmol/mol); FPG ≥126 mg/dL (≥7.0 mmol/L); 2-h PG ≥200 mg/dL (≥11.1 mmol/L) during OGTT; random plasma glucose ≥200 mg/dL (≥11.1 mmol/L) with classic symptoms of hyperglycemia or hyperglycemic crisis. In the absence of unequivocal hyperglycemia, diagnosis requires two abnormal results from different tests ... or the same test at two different time points.

American Diabetes Association Professional Practice Committee, 2. Diagnosis and Classification of Diabetes: Standards of Care in Diabetes—2026 (2026) · Table 2.1 Criteria for the diagnosis of diabetes in nonpregnant individuals · source

Not encoded: Type of diabetes (type 1, type 2, other) is not assessed. Conditions that make A1C unreliable (some haemoglobin variants, pregnancy, G6PD deficiency, HIV, anaemia, haemodialysis, erythropoietin; recommendation 2.4 and text) are not checked: A1C results are used as sent. No maximum interval between the two abnormal results is stated by the source and none is applied. Whether the test method is NGSP-certified and whether a fasting sample was truly fasting are asserted by the sender through the analyte name. When two different tests are discordant ADA advises repeating the abnormal test; this entry simply reports one abnormal result.

diabetes

None entered

Supported and specific

Code-family reference: Diabetes mellitus Coders only

reference for coders — the clinician's documented statement governs; the software does not assign codes

E11 Type 2 diabetes mellitus: distinguishes type 2 diabetes with or without complications by body system (kidney, eye, nerve, circulatory, skin, oral, hypoglycaemia, hyperglycaemia, ketoacidosis, hyperosmolarity), long-term drug use is separate (Z79) (87 codes in the category).

87 codes; see the official files

E10 Type 1 diabetes mellitus: distinguishes type 1 diabetes with the same complication axes as E11 (87 codes in the category).

87 codes; see the official files

Source: official ICD-10-CM FY2027 code descriptions (extract in library/data/code_reference_fy2027.json).

Hyperkalaemia
measured

ukka2026_hyperkalaemia@1.0 Draft · pending review

Criteria not met: Below 5.5 mmol/L

  • potassium serum 5.3 mmol/L 2026-11-12 07:00 · LM-P16-05

Window: 14 days before the check.

Citation

Hyperkalaemia and its severity (UK Kidney Association, July 2026 update)

ukka2026_hyperkalaemia@1.0
It is further classified by severity into mild (5.5-5.9 mmol/l), moderate (6.0-6.4 mmol/l) or severe (≥ 6.5 mmol/l).

UK Kidney Association, Clinical Practice Guidelines: Treatment of Acute Hyperkalaemia in Adults (2026) · Introduction, document page 9 (PDF page 10) · source

Contested: The guideline itself says 'There is no universally accepted definition of hyperkalaemia'; it adopts the ERC threshold of 5.5 mmol/L. CTCAE grades differ (see ctcae6_hyperkalaemia).

Not encoded: Pseudohyperkalaemia (guideline 15.3: haemolysis, delayed analysis, sampling technique) is not detected; a haemolysed sample is graded like any other unless the sender withholds it. Acute versus chronic (persistent) hyperkalaemia and the guideline's repeat-testing intervals (guidelines 1.2.1-1.2.3) are not encoded. ECG changes and clinical context are not assessed.

Not stated

None entered

Nothing to act on

Code-family reference: Hyperkalaemia Coders only

reference for coders — the clinician's documented statement governs; the software does not assign codes

E87 Other disorders of fluid, electrolyte and acid-base balance: distinguishes E87.5 hyperkalemia (one code; no severity axis) (14 codes in the category).

  • E87.0 Hyperosmolality and hypernatremia
  • E87.1 Hypo-osmolality and hyponatremia
  • E87.20 Acidosis, unspecified
  • E87.21 Acute metabolic acidosis
  • E87.22 Chronic metabolic acidosis
  • E87.29 Other acidosis
  • E87.3 Alkalosis
  • E87.4 Mixed disorder of acid-base balance
  • E87.5 Hyperkalemia
  • E87.6 Hypokalemia
  • E87.70 Fluid overload, unspecified
  • E87.71 Transfusion associated circulatory overload
  • E87.79 Other fluid overload
  • E87.8 Other disorders of electrolyte and fluid balance, not elsewhere classified

Source: official ICD-10-CM FY2027 code descriptions (extract in library/data/code_reference_fy2027.json).

Prediabetes
measured

ada2026_prediabetes@1.0 Draft · pending review

Criteria not met: A result is in the diabetes range — prediabetes not assigned; see ada2026_diabetes

  • hba1c 8.2 % 2026-09-12 09:00 · LM-P16-02

Window: 365 days before the check.

Citation

Prediabetes ranges (ADA Standards of Care 2026)

ada2026_prediabetes@1.0
A1C 5.7–6.4% (39–47 mmol/mol); FPG 100 mg/dL (5.6 mmol/L) to 125 mg/dL (6.9 mmol/L) (IFG); 2-h PG during 75-g OGTT 140 mg/dL (7.8 mmol/L) to 199 mg/dL (11.0 mmol/L) (IGT)

American Diabetes Association Professional Practice Committee, 2. Diagnosis and Classification of Diabetes: Standards of Care in Diabetes—2026 (2026) · Table 2.2 Criteria defining prediabetes in nonpregnant individuals · source

Contested: Other bodies (for example WHO) are understood to use a different impaired fasting glucose range and not to use an A1C prediabetes range; those texts were not opened, so no other thresholds are recorded. Review item.

Not encoded: ADA does not require confirmation for prediabetes in Table 2.2; none is applied. A1C reliability conditions are not checked (see ada2026_diabetes). Only the most recent result of each test is used.

Not stated

None entered

Nothing to act on

Code-family reference: Prediabetes Coders only

reference for coders — the clinician's documented statement governs; the software does not assign codes

R73 Elevated blood glucose level: distinguishes R73.01 impaired fasting glucose, R73.02 impaired glucose tolerance (oral), R73.03 prediabetes, R73.09 other abnormal glucose, R73.9 hyperglycaemia unspecified (5 codes in the category).

  • R73.01 Impaired fasting glucose
  • R73.02 Impaired glucose tolerance (oral)
  • R73.03 Prediabetes
  • R73.09 Other abnormal glucose
  • R73.9 Hyperglycemia, unspecified

Source: official ICD-10-CM FY2027 code descriptions (extract in library/data/code_reference_fy2027.json).